Heading 8535

Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, fuses, lightning arresters, voltage limiters, surge suppressors, plugs and other connectors, junction boxes), for a voltage exceeding 1,000 V

12 declarable lines

Heading 8535 covers high-voltage electrical apparatus used to switch, protect, or connect circuits, meaning apparatus rated above 1,000 V. It is split first by article type: fuses, automatic circuit breakers, isolating and make-and-break switches, lightning arresters and surge suppressors, and a residual other group. The other group separates motor starters and overload protectors from terminals, splices, couplings, and other connectors.

Products in this heading

  • High-voltage fuses rated for circuits of 2,300 V or more
  • High-voltage fuses for other circuits above 1,000 V
  • Automatic circuit breakers rated below 72.5 kV
  • Automatic circuit breakers for circuits of 345 kV or more
  • High-voltage knife isolating switches
  • Lightning arresters and surge suppressors
  • High-voltage motor starters and motor overload protectors
  • High-voltage terminals, electrical splices and couplings

How to choose the right subheading

  • Confirm the apparatus is rated for a voltage exceeding 1,000 V.
  • Identify the article type: fuse, automatic circuit breaker, isolating or make-and-break switch, lightning arrester or surge suppressor, or other.
  • For fuses, check whether the circuit is 2,300 V or more or other; for breakers, check whether the voltage is less than 72.5 kV or other and whether the circuit is 345 kV or more.
  • For isolating and make-and-break switches, check whether the switch is knife type or other.
  • For other apparatus, separate motor starters and overload protectors from terminals, splices, couplings, other connectors, and residual other.

Often confused with

  • Low-voltage switches, fuses, plugs and sockets rated at 1,000 V or less

    Heading 8536 covers the same types of apparatus at 1,000 V or less.

    Heading 8536
  • Assembled control panels with two or more heading 8535 or 8536 apparatus

    Heading 8537 covers boards, panels and consoles equipped with multiple switching or protection devices.

    Heading 8537
  • Parts made solely or principally for heading 8535 apparatus

    Heading 8538 covers parts for the apparatus of heading 8535, 8536 or 8537.

    Heading 8538
  • Electrical insulators

    Insulators are classified in heading 8546, not as switching or connecting apparatus.

    Heading 8546
  • Electrical transformers

    Transformers and static converters are in heading 8504, even when used in high-voltage circuits.

    Heading 8504

Frequently asked questions

What is the HTS code for high-voltage fuses?

Fuses for circuits of 2,300 V or more go in 8535.10.00.20 at a general (MFN) rate of 2.7%. Other fuses above 1,000 V go in 8535.10.00.40 at a general (MFN) rate of 2.7%.

What is the duty on high-voltage automatic circuit breakers?

Automatic circuit breakers for less than 72.5 kV go in 8535.21.00.00 at a general (MFN) rate of 2.7%. Other breakers in circuits of 345 kV or more go in 8535.29.00.20 at a general (MFN) rate of 2%, and other breakers go in 8535.29.00.40 at a general (MFN) rate of 2%.

How do I classify high-voltage surge suppressors or motor starters?

Lightning arresters, voltage limiters and surge suppressors go in 8535.40.00.00 at a general (MFN) rate of 2.7%. Motor starters and motor overload protectors for over 1,000 V go in 8535.90.40.00 at a general (MFN) rate of 2.7%.

Guide written from the official schedule text. Rates quoted are general (MFN) rates; check the line page for trade agreement rates and the classification of your exact product.